IP Ratings

IP Ratings
IP ratings International Protection ratings are covered in Australian Standard AS1939
IP Ratings
This system uses a two digit code to specify the degree of particle and water resistance of a luminaire
IP Ratings
The first digit indicates the degree of protection of the interior from the ingress of solid foreign objects
IP Ratings
The second digit indicates the degree of protection of the interior from the ingress of water

For example IP65 means: Complete protection against entry of dust & protection from a low pressure jet of water in any direction.

First Digit
 
Second Digit
 
IP Ratings
X
Not tested (no protection specified)
X
Not tested (no protection specified)
0
No protection provided
0
No protection provided
1
Protection against entry of objects larger than 50 square mm
1
Protection against drops of water falling vertically
2
Protection against entry of objects larger than 12 square mm
2
Protection against drops of water falling vertically when the luminaire is tilted up to 15 degrees from its normal position
3
Protection against entry of objects larger than 2.5 square mm
3
Protection from entry of water spray from angle of up to 60 degrees from vertical
4
Protection against entry of objects larger than 1.0 square mm
4
Protection from entry of water splashes or spray from any direction
5
Protection against entry of dust in sufficient quantity to prevent satisfactory operation
5
Protection from a low pressure jet of water in any direction
6
Complete protection against entry of dust
6
Protection against heavy seas or a strong jet of water in any direction
 
 
7
Protection against immersion up to 1 metre
 
 
8
Protection against submersion over 1 metre
lighting
light
Amps
Ballasts
Blocking Inductor
Colour Rendering
Colour Temperature
Current
Dimming
EMC Regulation
Emergency Lighting
Energy Efficiency
Glare Control
Glare Rating Systems
HPF
IP Ratings
Lamps
Lamp Efficiency
Lead Lag
Lighting Calculations
Light Emmitting Diodes
Lighting Measurements
Low Temperature Operation
Low Voltage Lighting
LPF
Lumen
Lumen Output of Lamps
Lux
Lux Levels
Mounting Heights
Mounting Terminology
Power
Power Factor
Ra
Resistance
Room Index
Terminology (General)
Triphosphor Lamps
Voltage
Watts
HOME ABOUT US PRODUCTS TECHNICAL CONTACT US
TERMS AND CONDITIONS
  WEBSITE DESIGN BY
Australian Explorer Travel Guide

HOSTING BY SPIT